| # | Summary | Link | Date |
1. | As a one-time solution for the projects ‘29338 Dominion Square West - South Side’ and ‘12389 Dominion Square West - North Side’, an additional etched helmet logo on tempered glass has been approved. Logo placement instruction ID-0000028-125 has been created. | OTS #19 / OTS #20 | 11/28/2024 |
2. | As a one-time solution for the project ‘25742 River Park South Block D’, a specific reflective sticker with letter "T" on tempered IGU's was implemented. Stickers were provided by Intus. | 3/12/2024 | |
3. | As a one-time solution for the project ‘25742 River Park South Block D’, a one-time instruction ID-0000028-100-1 for the placement of the "T" sticker on tempered glass has been prepared. | 4/2/2024 | |
4. | As a one-time solution for the project ‘19343 Ogden Commons Site 2A Building C,' a non-standard color RAL7042 for Enamel glass was approved. | 2/4/2025 | |
5. | As a one-time solution for the project '25835 1760 Jerome Ave', a total of 11 bent windows will be used. The IGU configurations, window dimensions, and radii have been coordinated and agreed upon with the supplier. | 7/31/2025 | |
6. | As a one-time solution for the projects ‘24435 10th and Irving (Joyce Motors)’, an additional etched helmet logo on tempered glass has been approved. Logo placement instruction ID-0000028-162 has been created. | 7/10/2025 | |
7. | As a one-time solution for the projects ‘26688 The Reserve at West Falls Church’, an additional etched helmet logo on positions with FL in a position name has been approved. Logo placement instruction ID-0000028-164.V1 has been created. | 8/21/2025 | |
8. | As a one-time solution for the project P20098 Port Chester Station Lofts – Port Chester (New Broad St), non-standard IGU structures with HP Silver 43/31 coating have been approved. | 1/6/2026 | |
9. | As an update to the one-time solution for the project P30956 The Chaucer Condo Tower – Houston (2360 Rice Blvd), the previously approved Ceramic enamel IGU structure was corrected. The final approved configuration is 4T/14Ar/6T_EN with a striped pattern in RAL1004 applied on surface #4 only. The stripe direction must be clearly indicated for each position in shop drawings. | 2/12/2026 | |
10. | As a one-time solution for the project P27938 Coney Landing – 2955 W 28th St, the use of Heat Strengthened frit glass was approved in place of fully tempered frit glass. The IGU structure was updated from Frit_4HST/18Ar/CG_4HS/18Ar/CG_4HS to Frit_4HS/18Ar/CG_4HS/18Ar/CG_4HS, based on supplier confirmation. | 2/25/2026 | |
11. | As a one-time solution for the project P32070 9 Taylor St., a non-standard IGU configuration was approved to meet the City of Somerville VLR/VLT requirements. The approved IGUs are 4_SN70s/18Ar/4/18Ar/Prem_4 and 4T_SN70s/18Ar/4T/18Ar/Prem_4T, replacing the previously specified SN51 configurations. | 2/25/2026 | |
12. | As a one-time solution for the project P33090 Flats Buildings – Fleet Landing at Nocatee (555a Cross Town Drive), a non-standard IGU using 66T (Tinted grey)/12Ar/SNX60_6 and 6T (Tinted grey)/12Ar/SN60_6T has been approved. | 5/6/2026 | |
13. | As a one-time solution for the project P26502 Fleet Landing at Nocatee – Assisted Living/Memory Care Building, a non-standard IGU using 6T (Tinted grey)/12Ar/SNX60_6 and 6T (Tinted grey)/12Ar/SN60_6T has been approved. | 5/4/2026 | |
14. | As a one-time solution for the project P27381 Crystal House 3 (501 20th Street South), etched Maltese Cross logos (4" × 4") were approved for selected IGUs. The drawing ID-0000028-196.V1 was prepared. | 4/2/2026 | |
15. | As a one-time solution for the project P24656 366 Broadway Residences Apartment (Somerville), a non-standard IGU configuration was approved to meet the City of Somerville VLR/VLT requirements. The approved IGUs are 4_SN70s/18Ar/4/18Ar/Prem_4 and 4T_SN70s/18Ar/4T/18Ar/Prem_4T. | 4/3/2026 | |
16. | As a one-time solution for the project P22244 1185 River Ave, the use of Heat Strengthened frit glass was approved in place of heat soaked frit glass. The IGU structure was updated from Frit_6HST/14Ar/CG_4HST to Frit_6HS/14Ar/CG_4HS, based on supplier confirmation. | 5/22/2026 | |
17. | As a one-time solution for the mock-up phase of P22244 1185 River Ave, a non-standard flipped IGU configuration was approved to match the tested glass assembly. Frit_6T6T.4/20Ar/CG_44.1 → Frit_4T4T.4/20Ar/CG_66.1 and 6.1/20Ar/CG_44.1 → 44.1/20Ar/CG_66.1. CANCELLED | 6/4/2026 | |
18. | As a one-time solution for P22244 1185 River Ave, non-standard flipped IGU configurations were approved to match the tested glass assembly. The client accepted the flipped configuration and the IGU supplier confirmed manufacturability. CANCELLED | 6/5/2026 | |
19. | As a one-time solution for the performance mock-up of P26551 Willets Point Phase 3, the standard IGU Frit_4T4T.4_SN51/20Ar/10HS was approved to be replaced with the non-standard configuration Frit_6HST6HST.4_SN51/20Ar/10HS. | 7/1/2026 | |