| # | Summary | Link | Date |
1. | As a one-time solution for the projects ‘29338 Dominion Square West - South Side’ and ‘12389 Dominion Square West - North Side’, an additional etched helmet logo on tempered glass has been approved. Logo placement instruction ID-0000028-125 has been created. | OTS #19 / OTS #20 | 11/28/2024 |
2. | As a one-time solution for the project ‘25742 River Park South Block D’, a specific reflective sticker with letter "T" on tempered IGU's was implemented. Stickers were provided by Intus. | 3/12/2024 | |
3. | As a one-time solution for the project ‘25742 River Park South Block D’, a one-time instruction ID-0000028-100-1 for the placement of the "T" sticker on tempered glass has been prepared. | 4/2/2024 | |
4. | As a one-time solution for the project ‘19343 Ogden Commons Site 2A Building C,' a non-standard color RAL7042 for Enamel glass was approved. | 2/4/2025 | |
5. | As a one-time solution for the project '25835 1760 Jerome Ave', a total of 11 bent windows will be used. The IGU configurations, window dimensions, and radii have been coordinated and agreed upon with the supplier. | 7/31/2025 | |
6. | As a one-time solution for the projects ‘24435 10th and Irving (Joyce Motors)’, an additional etched helmet logo on tempered glass has been approved. Logo placement instruction ID-0000028-162 has been created. | 7/10/2025 | |
7. | As a one-time solution for the projects ‘26688 The Reserve at West Falls Church’, an additional etched helmet logo on positions with FL in a position name has been approved. Logo placement instruction ID-0000028-164.V1 has been created. | 8/21/2025 | |
8. | As a one-time solution for the project P20098 Port Chester Station Lofts – Port Chester (New Broad St), non-standard IGU structures with HP Silver 43/31 coating have been approved. | 1/6/2026 | |
9. | As a one-time solution for the project P30956 The Chaucer Condo Tower – Houston (2360 Rice Blvd), a non-standard Ceramic enamel IGU has been approved: EN_4T/14Ar/6T_EN structure, with a striped pattern in RAL1004 on surface #2 and solid color RAL7016 on surface #4 | 1/13/2026 | |
10. | As a one-time solution for the project P27938 Coney Landing – 2955 W 28th St, the use of Heat Strengthened frit glass was approved in place of fully tempered frit glass. The IGU structure was updated from Frit_4T4T.4_SN51/10Ar/6HS/14Ar/CG_6HS to Frit_4HS4HS.4_SN51/10Ar/6HS/14Ar/CG_6HS, based on supplier confirmation. | 1/22/2026 |